PHYSICAL CHARACTERISTICS
 Size: (3U) 5.25” H x 19” W x 19.1” D
 Weight: 40 lbs. Aluminum Chassis

ELECTRICAL CHARACTERISTICS
 Power – Standard: Three phase WYE and DELTA 95 - 125 Vac,
47 - 440 Hz
 Power – Optional: • Single Phase   Autoranging 95 - 240   Vac, 47 - 440 Hz
• +18 - 32 Vdc (optional)
 DC Outputs: +5 Vdc @ 70A,
+12 Vdc @ 20A,
-12 Vdc @ 10A
 Voltage Holdup: Per MIL-STD-704A, 50ms for 650W Load
 Power Consumption: 350W Standard (dc)

PERFORMANCE CHARACTERISTICS
Backplane: 5 Slot VME – Single or Multiples
I/O Panels: Rear panel for both P2 and Face Plate Connections
Cooling: Covection Cooled – Maximum 120 CFM, Fans are environmentally speed controlled
Temperature Sensing: System monitor constantly measures selected temperature points
Power Supply: System monitor constantly measures input AC voltage and DC voltage outputs
Peripheral Bay: Configurable with various peripherals
 
DataMetrics™ rugged chassis are designed to meet and exceed military, industrial, or customer defined specifications. System integration can be accomplished by adding software, I/O (digital and analog), single board computers, or other functionality. The Model 7103 comes with a fully customizable 5 slot VME backplane and can be custom configured with various peripherals. This chassis supports popular backplanes such as VME, VME 64X, VITA 31, VITA 41, VITA 46, CompactPCI 2.1, CompactPCI 2.16, and more. The power supplies used are fully configurable to meet all output voltages and current requirements and provide optional voltage margining for circuit development and system characterization. The optional Ethernet based system monitor can track chassis temperature, input voltages, fan speed, and more. Contact DataMetrics™ to design your custom chassis today!.

Model 7103 Chassis Data Sheet - PDF


ENVIRONMENTAL CHARACTERISTICS
 Temperature: Operating: -25°C to 55°C     Storage: -40°C to 70°C
 Humidity: 10% to 95%, Non-condensing
 Explosive Atmosphere: MIL-STD-810E, Method 511.3
 Fungus: MIL-STD-810E, Method 508.4
 Orientation: ±45° from horizontal, any axis
 Vibration: 5g Sinusoidal and Random per MIL-STD-810E, Method 514.4,
Procedure I
 Shock: MIL-STD-810E, Method 516.4, Procedure VI
Operating: 15G     Non-operating: 20G
 Altitude: Operating: 15,000 ft.     Non-operating: 50,000 ft.
 EMI/EMC: MIL-STD-461E, CE01, CE03, CS01, CS02, CS06, RE02, RS02, RS03
 ESD: MIL-STD-1686A