            | PHYSICAL 
              CHARACTERISTICS 
                      
                        | Size: | 7.8" H x 10" 
                          W x 17" D |  
                        | Weight: | 29 lbs. Aluminum Chassis |  ELECTRICAL CHARACTERISTICS
 
                
                  | Power 
                    – Standard: | Three 
                    phase WYE 115 Vac, 47 - 440 Hz |  
                  | DC Outputs: | ±5 Vdc @ 30A, ±12 Vdc @ 6.2A,
 -12 Vdc @ 6.2A
 |  
                  | Voltage 
                    Holdup: | 10ms |  
                  | Power 
                    Consumption: | 150W Max |  PERFORMANCE CHARACTERISTICS
 
                
                  | Backplane: | 9 Slot 
                    VME 64X (Single or Multiple) |  
                  | I/O Panels: | Front Panel I/O Connections |  
                  | Cooling: | Forced air cooling |  
                  | Temperature 
                    Sensing: | Temperature monitored constantly |  | 
              
                | 
                  
                    |  |  
                    | The Model 8211 is a Full-Long ATR with a 9-slot VME64x or 8-slot CompactPCI backplane standard. The
 hybrid (convection and conduction) cooling system
 provides superior performance and a wide operational
 temperature range of -32ºC to 65ºC.
  Like all DataMetrics™ rugged chassis, the Model8211 is designed to meet and exceed multiple military
 specifications, and is custom configurable with many
 backplane, power supply, and other options available.
 An embedded shock-isolated HDD or Ethernet based
 system monitor/control are available as options.
 In additional to the Model 8211, fully sealed, conduction
                        cooled ATR’s are also available in all 13 standard sizes.
 |  
                    | Model 8211 
                            ATR Data Sheet - PDF  |  |  |  
            | ENVIRONMENTAL CHARACTERISTICS 
                      
                        | Temperature: | Operating: 
                          -32°C to 65°C     Storage: 
                          -40°C to 70°C |  
                        | Humidity: | 10% to 95%, Non-condensing |  
                        | Explosive 
                          Atmosphere: | MIL-STD-810E, Method 
                          511.3 |  
                        | Fungus: | MIL-STD-810E, Method 508.4 |  
                        | Orientation: | ±45° from 
                          horizontal, any axis |  
                        | Vibration: | 5g 15-2000 Hz per MIL-STD-810E, Sinusoidal and Random |  
                        | Shock: | MIL-STD-810E, Method 
                          516.4, Procedure VI Operating: 15G     Non-operating: 
                          20G
 |  
                        | Altitude: | Operating: 15,000 ft.     Non-operating: 
                          50,000 ft. |  
                        | EMI/EMC: | MIL-STD-461D, CE01, CE03, CS01, CS02, 
                          CS06, RE02, RS02, RS03 |  
                        | ESD: | MIL-STD-1686A |  |  |  |  |  |